Features
Performance in a convenient, compact size
Omya’s Syringe pump is designed to enhance safety while maintaining simplicity, independently and together to accurately deliver infusions whilst helping protect each patients of all ages. syringe pump platform has been recognized for its accurate medication delivery in critical care and neonate infusion.
Technical Specifications
Infusion Specifications
Infusion Channel
Dual channel Infusion
Compatible Syringe Size/Capacity
5 ml, 10 ml, 20 ml, 30 ml, 50 ml /60 ml syringes
Syringe used should meet the requirements of ISO 7886-1:
Sterile hypodermic syringes for single use.
Syringe Detection / Calibration
Pre-Calibrated Syringe settings for SEVEN Standard Brands,
Auto-Calibration for TWO customized user syringe
Dose Rate Units
ml/h, mg/kg/h, µg/kg/min
Flow Rate Accuracy
Accuracy including syringe:
within ± 2%,
Mechanical accuracy:
within ± 1%
KVO Rate
At the completion of a infusion, the pump will infuse at the KVO rate
configured or the current infusion rate, whichever is lower.
The default KVO rate is set at 1 mL/hr but may be configured
to between 0.1 – 5.0 mL/hr.
Occlusion Detection Pressure
Low, Medium and High occl. pr.
from 300 to 900 mmHg (40-120KPa),
‘Low’:40 to 60 kPa,
‘Mid’ :61 -90 kPa,
‘High’: 91 -120 kPa,
Bolus rate
5 ml syringe:50~100 ml/h,
10 ml syringe:50~200 ml/h,
20 ml syringe:50~400 ml/h
30 ml syringe:50~600 ml/h,
50 ml syringe:50~1500 ml/h
Purge rate
5 ml syringe: 100 ml/h,
10 ml syringe: 200 ml/h,
20 ml syringe: 400 ml/h
30 ml syringe: 600 ml/h,
50 ml syringe: 1500 ml/h
Display Information
‘Syringe Brand’, ‘Syringe Size’, ‘Flow Rate’,
‘Preset Volume’, ‘Volume Infused’,‘Alarm Information’,
‘Line Pressure Indicator’,‘Battery Charge Indicator’,
‘Auto Lock’, ‘Bed Number’
Safety Alarm Information
‘Occlusion’, ‘Near Preset VOL’, ‘Near Syr. Empty’,
‘AC Power OFF’, ‘Infused/KVO’, ‘Syringe Empty’,
‘Purging’, ‘Confirm/Back’, ‘Check Syr. Clamp’,
‘Plunger Disengaged’, ‘Check Plunger Holder’,
‘Flow Rate Error’, ‘Low Battery’, ‘Purging Over’,
‘System Error’.
Infusion Mode
Rate Mode, Time Mode,
Body Weight Mode, Link Mode
Flow Rate Range
0.1~100 ml/h (0.1 ml/h step) 5 ml syringe,
0.1~200 ml/h (0.1 ml/h step) 10 ml syringe,
0.1~400 ml/h (0.1 ml/h step) 20 ml syringe,
0.1~600 ml/h (0.1 ml/h step) 30 ml syringe,
0.1~1500 ml/h (0.1 ml/h step) 50/60 ml syringe
Increment of rate
0.1ml/h-999.9ml/h, the increment is 0.1ml/h
1000 ml/h -1500 ml/h, the increment is 1ml/h
Mass Unit Programming Range
Patient Weight: 0-300 Kg,
Drug Mass: 0~999.9 mg
Drug Volume: 0~999.9 ml,
Unit options: mg/kg/h, µg/kg/min
Accumulated Volume
0.1~9999.9ml
Preset Volume / Time Limit
0.1~999.9ml / 1 – 2000 mins (Appro. 33 Hrs)
Bolus Functions
‘Hands free bolus – Auto Bolus Mode’ ,
‘Hands on Bolus – Manual bolus’
Maximum Bolus volume
5 ml syringe: 1ml;
10 ml syringe: 5ml;
20 ml syringe: 10 ml;
30 ml syringe: 20 ml;
50 ml syringe: 25ml
Standby time range
00:01-99:59 hh:mm
Alarm Indication - Safety Features
Visual Alarm:
Dual Redundant Visual Alarms both side of the device,
indicates with two priority colors:
Red (High Priority) and Yellow (Low and Mid Priority)
AC/DC indicator :
Light 1 (green)
Battery indicator :
Light 1 (green)
Syringe Brand and Compatible Syringe sizes
The pump is calibrated and labelled for use with
single-use disposable luer lock syringes.
Only use the size and type of syringe
specified on the pump display.
B.Braun : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
B.D : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Dispo Van : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Nipro : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Safti : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Romsons : 5 mL, 10 mL, 20 mL, 50/60 mL
General Specifications
Display
Screen :
3.0 inch Color LCD screen Display
Resolution:
240 x 128 pixels
Communication Interfaces
Interface ports :
Ambulatory port / 12VDC input,
Nurse Staff Call,
RS 232 – Serial Data port
Power Supply
Integrated Power Supply,
Rated Voltage :
AC 100~240 V, 50~60 Hz,
Power Consumption :
25 VA
External DC power supply :
12V DC supply
Physical Dimensions
Dimension (L) x (W) x (H) in mm:
260 x 138 x 245
Weight :
3.7 kg (with clamp base)
Battery
Battery Capacity :
Advanced Rechargeable Lithium Polymer battery –
7.4 V, 4000 mAh (1 Internal battery)
Battery life :
Continuously operate for 6-8 hrs from Full Charge
(at a rate of 5 ml/h at 30°C under Normal Conditions)
Battery Recharge :
When AC Power is ON,
Battery will Automatically Recharge
(about 5 hrs to 90% charge ),
When the pump is off,
the charging time is not longer than 4 hrs
External Fuse
1.5 A / 250 V (User Replaceable)
Environmental Conditions
Operation Conditions:
Ambient temperature: + 5 to + 40°C,
Atmosphere Pressure: 86 ~106 kPa,
Relative humidity: ≤ 80%
Storage Conditions :
Ambient temperature: – 20 to +55°C,
Atmosphere Pressure: 50 ~106 kPa,
Relative humidity: ≤ 95%
Compliance & Essential Performance
Flow Rate Accuracy
Accuracy including syringe:
within ± 2%,
Mechanical accuracy:
within ± 1%
Electrical Safety Protection
Class II protective and internal power supply,
BF Type Equipment,
Mode of operation : 100 % (continuous operation)
Visual Alarm Indication
Visual Alarms indicates with two priority colors:
Red (High Priority) and
Yellow (Low and Mid Priority),
meets according to the IEC 60601-1-8 standard requirements.
Essential Performance
Infusion of liquids without variation of infusion rate
Pressure limitation as protection from the bursting of the infusion line
Protection from air-infusion
Protection against unintended bolus volumes and occlusion (added by IEC60601-2-24)
Alarm signal of high priority (added by IEC 60601-2-24)
Classification
EN / IEC 60601-1 and EN / IEC 60601-2-24 / EMC
Under process – CE Marking in Compliance with the
EU MDR 2017/745 (European Medical Device Regulation)
Class (acc. to Directive 93/42 EEC) : Class IIb
Ingress Protection
Ingress Protection – IP 44
(Complete protection against ingress of
small solid foreign bodies and Water splashed
against the Device from any direction)
Audio Alarm Volume :
Support multi-level volume functions
with the sound pressure range from 59-74 dB(A)
and key pad beep;
The alarm sound meets according to
the IEC 60601-1-8 standard requirements.
Optional Features
Event Log Review
Approximately one year event log of normal use and
Min. 2000 records with time and date
Infusion Management (Optional)
Extensive data connectivity with
Omya’s IMS240i, IMS460i model
(Infusion Monitoring System)
Wireless LAN (Optional)
Wireless Data Transmission compatible with Patient Data Management Systems (Optional)
Nurse Staff call (Optional)
Max. 24 V / 0,5 A / 24 VA
- Infusion Specifications
-
Infusion Specifications
Infusion Channel
Dual channel Infusion
Compatible Syringe Size/Capacity
5 ml, 10 ml, 20 ml, 30 ml, 50 ml /60 ml syringes
Syringe used should meet the requirements of ISO 7886-1:
Sterile hypodermic syringes for single use.Syringe Detection / Calibration
Pre-Calibrated Syringe settings for SEVEN Standard Brands,
Auto-Calibration for TWO customized user syringeDose Rate Units
ml/h, mg/kg/h, µg/kg/min
Flow Rate Accuracy
Accuracy including syringe:
within ± 2%,
Mechanical accuracy:
within ± 1%KVO Rate
At the completion of a infusion, the pump will infuse at the KVO rate
configured or the current infusion rate, whichever is lower.
The default KVO rate is set at 1 mL/hr but may be configured
to between 0.1 – 5.0 mL/hr.Occlusion Detection Pressure
Low, Medium and High occl. pr.
from 300 to 900 mmHg (40-120KPa),‘Low’:40 to 60 kPa,
‘Mid’ :61 -90 kPa,
‘High’: 91 -120 kPa,Bolus rate
5 ml syringe:50~100 ml/h,
10 ml syringe:50~200 ml/h,
20 ml syringe:50~400 ml/h
30 ml syringe:50~600 ml/h,
50 ml syringe:50~1500 ml/hPurge rate
5 ml syringe: 100 ml/h,
10 ml syringe: 200 ml/h,
20 ml syringe: 400 ml/h
30 ml syringe: 600 ml/h,
50 ml syringe: 1500 ml/hDisplay Information
‘Syringe Brand’, ‘Syringe Size’, ‘Flow Rate’,
‘Preset Volume’, ‘Volume Infused’,‘Alarm Information’,
‘Line Pressure Indicator’,‘Battery Charge Indicator’,
‘Auto Lock’, ‘Bed Number’Safety Alarm Information
‘Occlusion’, ‘Near Preset VOL’, ‘Near Syr. Empty’,
‘AC Power OFF’, ‘Infused/KVO’, ‘Syringe Empty’,
‘Purging’, ‘Confirm/Back’, ‘Check Syr. Clamp’,
‘Plunger Disengaged’, ‘Check Plunger Holder’,
‘Flow Rate Error’, ‘Low Battery’, ‘Purging Over’,
‘System Error’.Infusion Mode
Rate Mode, Time Mode,
Body Weight Mode, Link ModeFlow Rate Range
0.1~100 ml/h (0.1 ml/h step) 5 ml syringe,
0.1~200 ml/h (0.1 ml/h step) 10 ml syringe,
0.1~400 ml/h (0.1 ml/h step) 20 ml syringe,
0.1~600 ml/h (0.1 ml/h step) 30 ml syringe,
0.1~1500 ml/h (0.1 ml/h step) 50/60 ml syringeIncrement of rate
0.1ml/h-999.9ml/h, the increment is 0.1ml/h
1000 ml/h -1500 ml/h, the increment is 1ml/hMass Unit Programming Range
Patient Weight: 0-300 Kg,
Drug Mass: 0~999.9 mg
Drug Volume: 0~999.9 ml,
Unit options: mg/kg/h, µg/kg/minAccumulated Volume
0.1~9999.9ml
Preset Volume / Time Limit
0.1~999.9ml / 1 – 2000 mins (Appro. 33 Hrs)
Bolus Functions
‘Hands free bolus – Auto Bolus Mode’ ,
‘Hands on Bolus – Manual bolus’Maximum Bolus volume
5 ml syringe: 1ml;
10 ml syringe: 5ml;
20 ml syringe: 10 ml;
30 ml syringe: 20 ml;
50 ml syringe: 25mlStandby time range
00:01-99:59 hh:mm
Alarm Indication - Safety Features
Visual Alarm:
Dual Redundant Visual Alarms both side of the device,
indicates with two priority colors:
Red (High Priority) and Yellow (Low and Mid Priority)AC/DC indicator :
Light 1 (green)Battery indicator :
Light 1 (green)Syringe Brand and Compatible Syringe sizes
The pump is calibrated and labelled for use with
single-use disposable luer lock syringes.
Only use the size and type of syringe
specified on the pump display.
B.Braun : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
B.D : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Dispo Van : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Nipro : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Safti : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Romsons : 5 mL, 10 mL, 20 mL, 50/60 mL - General Specifications
-
General Specifications
Display
Screen :
3.0 inch Color LCD screen Display
Resolution:
240 x 128 pixelsCommunication Interfaces
Interface ports :
Ambulatory port / 12VDC input,
Nurse Staff Call,
RS 232 – Serial Data portPower Supply
Integrated Power Supply,
Rated Voltage :
AC 100~240 V, 50~60 Hz,
Power Consumption :
25 VA
External DC power supply :
12V DC supplyPhysical Dimensions
Dimension (L) x (W) x (H) in mm:
260 x 138 x 245
Weight :
3.7 kg (with clamp base)Battery
Battery Capacity :
Advanced Rechargeable Lithium Polymer battery –
7.4 V, 4000 mAh (1 Internal battery)Battery life :
Continuously operate for 6-8 hrs from Full Charge
(at a rate of 5 ml/h at 30°C under Normal Conditions)Battery Recharge :
When AC Power is ON,
Battery will Automatically Recharge
(about 5 hrs to 90% charge ),
When the pump is off,
the charging time is not longer than 4 hrsExternal Fuse
1.5 A / 250 V (User Replaceable)
Environmental Conditions
Operation Conditions:
Ambient temperature: + 5 to + 40°C,
Atmosphere Pressure: 86 ~106 kPa,
Relative humidity: ≤ 80%Storage Conditions :
Ambient temperature: – 20 to +55°C,
Atmosphere Pressure: 50 ~106 kPa,
Relative humidity: ≤ 95% - Compliance & Essential Performance
-
Compliance & Essential Performance
Flow Rate Accuracy
Accuracy including syringe:
within ± 2%,Mechanical accuracy:
within ± 1%Electrical Safety Protection
Class II protective and internal power supply,
BF Type Equipment,
Mode of operation : 100 % (continuous operation)Visual Alarm Indication
Visual Alarms indicates with two priority colors:
Red (High Priority) and
Yellow (Low and Mid Priority),
meets according to the IEC 60601-1-8 standard requirements.Essential Performance
Infusion of liquids without variation of infusion rate
Pressure limitation as protection from the bursting of the infusion line
Protection from air-infusion
Protection against unintended bolus volumes and occlusion (added by IEC60601-2-24)
Alarm signal of high priority (added by IEC 60601-2-24)Classification
EN / IEC 60601-1 and EN / IEC 60601-2-24 / EMC
Under process – CE Marking in Compliance with the
EU MDR 2017/745 (European Medical Device Regulation)Class (acc. to Directive 93/42 EEC) : Class IIb
Ingress Protection
Ingress Protection – IP 44
(Complete protection against ingress of
small solid foreign bodies and Water splashed
against the Device from any direction)Audio Alarm Volume :
Support multi-level volume functions
with the sound pressure range from 59-74 dB(A)
and key pad beep;
The alarm sound meets according to
the IEC 60601-1-8 standard requirements. - Optional Features
-
Optional Features
Event Log Review
Approximately one year event log of normal use and
Min. 2000 records with time and dateInfusion Management (Optional)
Extensive data connectivity with
Omya’s IMS240i, IMS460i model
(Infusion Monitoring System)Wireless LAN (Optional)
Wireless Data Transmission compatible with Patient Data Management Systems (Optional)
Nurse Staff call (Optional)
Max. 24 V / 0,5 A / 24 VA
Related Products
Request a quick quote
If you have request of our products or you are interested in any other medical products,
please leave messages below and we’ll reply you soon as possible within 24 hours.