S550s

S550i Syringe Infusion Pump

S550s is a Single Channel Syringe Infusion Pump is Simple, Compact and intuitive configuration of the pump designed for the safe and efficient delivery, provides a user-friendly solution to complex therapies in all clinical areas.

Benefits

Designed to facilitate

An intuitive yet meaningful design, balanced in all aspect of the experience through aesthetic, function, and ergonomic. Designed to facilitate clinician with comprehensive range of feature and a high degree of safety, performance, flexibility, intuitive operation, and exceptional reliability enhance your confidence to provide seamless patient care

Simple User-friendly Interface

Compact, light weight pump easing bedside mounting, portable and transport workflow, 3″ color widescreen display for distance monitoring, numeric keypads for fast input, quick access setting keys and dual redundant visual alarm, Ease of operation with simple intuitive use interface provides easy navigation and increase clinical efficiency

Robust and Durable

IP44 grade dust/waterproof resistance, eliminating concerns around accidental fluid splash and Withstands drop damage, impacts, vibration during clinical usage. To prevent unscheduled downtime or system failures to help maximize your equipment performance, the device has undergone and passed rigorous environmental, safety and EMC tests.

Performance and accuracy

With latest technological advancements increases safety, functionality considering the unmet need of care provider. A microprocessor controlled high-precision stepper motor, driving system offers comprehensive range of features which is capable of accurately controlling the delivery rate, monitoring infusion course makes it ideal for critical care & neonatal infusion.

Features
Performance in a convenient, compact size

Omya’s Syringe pump is designed to enhance safety while maintaining simplicity, independently and together to accurately deliver infusions whilst helping protect each patients of all ages. syringe pump platform has been recognized for its accurate medication delivery in critical care and neonate infusion.

null

Advanced Infusion Modes

Rate mode, Time mode, Body Weight
mode, Dose mode and Program mode
null

All Vital Infusion Options

Administering Infusions, Bolus, KVO, Purge
null

Auto Syringe Calibrations & Detections

Pre-calibrated 7 Standard Syringe Brands,
2 Custom User Syringe Calibrations
null

Rechargeable Lithium Polymer Battery

Advanced Rechargeable Lithium polymer Battery
with 6000mAh, Operates for 5-7 hrs from Full Charge
null

Communication Interfaces

Nurse call, RS232 and Ambulatory Port
null

Electrical Safety & Ingress Protection

Level Class II, Type-BF, IP44 (Dust and Fluid Resistance)
null

State of the Art Technology

Dual Micro-controller, Driven by Precise Stepper Motor, Concealed
Mechanism, Quiet Operation Communication Interfaces
null

Ergonomic Design

3 inch Wide LCD display, Recessed Handle,
Numeric Keypad for Fast Input and Quick Access Setting
null

Safety Features

Dual Visual Alarms, Automatic keypad Lock Activation,
Dynamic Occlusion Detection, Anti-Bolus Functions
null

Bolus Functions

‘Hands-free’ and ‘Hands-on’ Bolus
null

Extensive Data Connectivity

Compatible with Infusion/Patient Data Management System
null

Fluid Management system

Optional Wireless Interface with Fluid Monitoring

Technical Specifications

Infusion Specifications

Infusion Channel

Single channel Infusion

Compatible Syringe Size/Capacity

5 ml, 10 ml, 20 ml, 30 ml, 50 ml /60 ml syringes

Syringe used  should meet the requirements of ISO 7886-1:
Sterile hypodermic syringes for single use.

Syringe Detection / Calibration

Pre-Calibrated Syringe settings for SEVEN Standard Brands,
Auto-Calibration for TWO customized user syringe

Dose Rate Units

ml/h, mg/kg/h, µg/kg/min

Flow Rate Accuracy

Accuracy including syringe:
within ± 2%,
Mechanical accuracy:
within ± 1%

KVO Rate

At the completion of a infusion, the pump will infuse at the KVO rate
configured or the current infusion rate, whichever is lower.
The default KVO rate is set at 1 mL/hr but may be configured
to between 0.1 – 5.0 mL/hr.

Occlusion Detection Pressure

Low, Medium and High occl. pr.
from 300 to 900 mmHg (40-120KPa),

‘Low’:40 to 60 kPa,
‘Mid’ :61 -90 kPa,
‘High’: 91 -120 kPa,

Bolus rate

5 ml syringe:50~100 ml/h,
10 ml syringe:50~200 ml/h,
20 ml syringe:50~400 ml/h
30 ml syringe:50~600 ml/h,
50 ml syringe:50~1500 ml/h

Purge rate

5 ml syringe: 100 ml/h,
10 ml syringe: 200 ml/h,
20 ml syringe: 400 ml/h
30 ml syringe: 600 ml/h,
50 ml syringe: 1500 ml/h

Display Information

‘Syringe Brand’, ‘Syringe Size’, ‘Flow Rate’,
‘Preset Volume’, ‘Volume Infused’,‘Alarm Information’,
‘Line Pressure Indicator’,‘Battery Charge Indicator’,
‘Auto Lock’, ‘Bed Number’

Safety Alarm Information

‘Occlusion’, ‘Near Preset VOL’, ‘Near Syr. Empty’,
‘AC Power OFF’, ‘Infused/KVO’, ‘Syringe Empty’,
‘Purging’, ‘Confirm/Back’, ‘Check Syr. Clamp’,
‘Plunger Disengaged’, ‘Check Plunger Holder’,
‘Flow Rate Error’, ‘Low Battery’, ‘Purging Over’,
‘System Error’.

Infusion Mode

Rate Mode, Time Mode, Body Weight Mode

Flow Rate Range

0.1~100 ml/h (0.1 ml/h step) 5 ml syringe,
0.1~200 ml/h (0.1 ml/h step) 10 ml syringe,
0.1~400 ml/h (0.1 ml/h step) 20 ml syringe,
0.1~600 ml/h (0.1 ml/h step) 30 ml syringe,
0.1~1500 ml/h (0.1 ml/h step) 50/60 ml syringe

Increment of rate

0.1ml/h-999.9ml/h, the increment is 0.1ml/h
1000 ml/h -1500 ml/h, the increment is 1ml/h

Mass Unit Programming Range

Patient Weight: 0-300 Kg,
Drug Mass: 0~999.9 mg
Drug Volume: 0~999.9 ml,
Unit options: mg/kg/h, µg/kg/min

Accumulated Volume

0.1~9999.9ml

Preset Volume / Time Limit

0.1~999.9ml / 1 – 2000 mins (Appro. 33 Hrs)

Bolus Functions

‘Hands free bolus – Auto Bolus Mode’ ,
‘Hands on Bolus – Manual bolus’

Maximum Bolus volume

5 ml syringe: 1ml;
10 ml syringe: 5ml;
20 ml syringe: 10 ml;
30 ml syringe: 20 ml;
50 ml syringe: 25ml

Standby time range

00:01-99:59 hh:mm

Alarm Indication - Safety Features

Visual Alarm:
Dual Redundant Visual Alarms both side of the device,
indicates with two priority colors:
Red (High Priority) and Yellow (Low and Mid Priority)

AC/DC indicator :
Light 1 (green)

Battery indicator :
Light 1 (green)

Syringe Brand and Compatible Syringe sizes

The pump is calibrated and labelled for use with
single-use disposable luer lock syringes.
Only use the size and type of syringe
specified on the pump display.
B.Braun : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
B.D : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Dispo Van : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Nipro : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Safti : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Romsons : 5 mL, 10 mL, 20 mL, 50/60 mL

General Specifications

Display

Screen :
3.0 inch Color LCD screen Display
Resolution:
240 x 128 pixels

Communication Interfaces

Interface ports :
Ambulatory port / 12VDC input,
Nurse Staff Call,
RS 232 – Serial Data port

Power Supply

Integrated Power Supply,
Rated Voltage :
AC 100~240 V, 50~60 Hz,
Power Consumption :
25 VA
External DC power supply :
12V DC supply

Physical Dimensions

Dimension (L) x (W) x (H) in mm:
260 x 148.5 x 134
Weight :
2.2 kg (with clamp base)

Battery

Battery Capacity :
Advanced Rechargeable Lithium Polymer battery –
7.4 V, 4000 mAh (1 Internal battery)

Battery life :
Continuously operate for 6-8 hrs from Full Charge
(at a rate of 5 ml/h at 30°C under Normal Conditions)

Battery Recharge :
When AC Power is ON,
Battery will Automatically Recharge
(about 5 hrs to 90% charge ),
When the pump is off,
the charging time is not longer than 4 hrs

External Fuse

1.5 A / 250 V (User Replaceable)

Environmental Conditions

Operation Conditions:
Ambient temperature: + 5 to + 40°C,
Atmosphere Pressure: 86 ~106 kPa,
Relative humidity: ≤ 80%

Storage Conditions :
Ambient temperature: – 20 to +55°C,
Atmosphere Pressure: 50 ~106 kPa,
Relative humidity: ≤ 95%

Compliance & Essential Performance

Flow Rate Accuracy

Accuracy including syringe:
within ± 2%,

Mechanical accuracy:
within ± 1%

Electrical Safety Protection

Class II protective and internal power supply,
BF Type Equipment,
Mode of operation : 100 % (continuous operation)

Visual Alarm Indication

Visual Alarms indicates with two priority colors:
Red (High Priority) and
Yellow (Low and Mid Priority),
meets according to the IEC 60601-1-8 standard requirements.

Essential Performance

Infusion of liquids without variation of infusion rate
Pressure limitation as protection from the bursting of the infusion line
Protection from air-infusion
Protection against unintended bolus volumes and occlusion (added by IEC60601-2-24)
Alarm signal of high priority (added by IEC 60601-2-24)

Classification

EN / IEC 60601-1 and EN / IEC 60601-2-24 / EMC
Under process – CE Marking in Compliance with the
EU MDR 2017/745 (European Medical Device Regulation)

Class (acc. to Directive 93/42 EEC) : Class IIb

Ingress Protection

Ingress Protection – IP 44
(Complete protection against ingress of
small solid foreign bodies and Water splashed
against the Device from any direction)

Audio Alarm Volume :

Support multi-level volume functions
with the sound pressure range from 59-74 dB(A)
and key pad beep;
The alarm sound meets according to
the IEC 60601-1-8 standard requirements.

Optional Features

Event Log Review

Approximately one year event log of normal use and
Min. 2000 records with time and date

Infusion Management (Optional)

Extensive data connectivity with
Omya’s IMS240i, IMS460i model
(Infusion Monitoring System)

Wireless LAN (Optional)

Wireless Data Transmission compatible with Patient Data Management Systems (Optional)

Nurse Staff call (Optional)

Max. 24 V / 0,5 A / 24 VA

Infusion Specifications

Infusion Specifications

Infusion Channel

Single channel Infusion

Compatible Syringe Size/Capacity

5 ml, 10 ml, 20 ml, 30 ml, 50 ml /60 ml syringes

Syringe used  should meet the requirements of ISO 7886-1:
Sterile hypodermic syringes for single use.

Syringe Detection / Calibration

Pre-Calibrated Syringe settings for SEVEN Standard Brands,
Auto-Calibration for TWO customized user syringe

Dose Rate Units

ml/h, mg/kg/h, µg/kg/min

Flow Rate Accuracy

Accuracy including syringe:
within ± 2%,
Mechanical accuracy:
within ± 1%

KVO Rate

At the completion of a infusion, the pump will infuse at the KVO rate
configured or the current infusion rate, whichever is lower.
The default KVO rate is set at 1 mL/hr but may be configured
to between 0.1 – 5.0 mL/hr.

Occlusion Detection Pressure

Low, Medium and High occl. pr.
from 300 to 900 mmHg (40-120KPa),

‘Low’:40 to 60 kPa,
‘Mid’ :61 -90 kPa,
‘High’: 91 -120 kPa,

Bolus rate

5 ml syringe:50~100 ml/h,
10 ml syringe:50~200 ml/h,
20 ml syringe:50~400 ml/h
30 ml syringe:50~600 ml/h,
50 ml syringe:50~1500 ml/h

Purge rate

5 ml syringe: 100 ml/h,
10 ml syringe: 200 ml/h,
20 ml syringe: 400 ml/h
30 ml syringe: 600 ml/h,
50 ml syringe: 1500 ml/h

Display Information

‘Syringe Brand’, ‘Syringe Size’, ‘Flow Rate’,
‘Preset Volume’, ‘Volume Infused’,‘Alarm Information’,
‘Line Pressure Indicator’,‘Battery Charge Indicator’,
‘Auto Lock’, ‘Bed Number’

Safety Alarm Information

‘Occlusion’, ‘Near Preset VOL’, ‘Near Syr. Empty’,
‘AC Power OFF’, ‘Infused/KVO’, ‘Syringe Empty’,
‘Purging’, ‘Confirm/Back’, ‘Check Syr. Clamp’,
‘Plunger Disengaged’, ‘Check Plunger Holder’,
‘Flow Rate Error’, ‘Low Battery’, ‘Purging Over’,
‘System Error’.

Infusion Mode

Rate Mode, Time Mode, Body Weight Mode

Flow Rate Range

0.1~100 ml/h (0.1 ml/h step) 5 ml syringe,
0.1~200 ml/h (0.1 ml/h step) 10 ml syringe,
0.1~400 ml/h (0.1 ml/h step) 20 ml syringe,
0.1~600 ml/h (0.1 ml/h step) 30 ml syringe,
0.1~1500 ml/h (0.1 ml/h step) 50/60 ml syringe

Increment of rate

0.1ml/h-999.9ml/h, the increment is 0.1ml/h
1000 ml/h -1500 ml/h, the increment is 1ml/h

Mass Unit Programming Range

Patient Weight: 0-300 Kg,
Drug Mass: 0~999.9 mg
Drug Volume: 0~999.9 ml,
Unit options: mg/kg/h, µg/kg/min

Accumulated Volume

0.1~9999.9ml

Preset Volume / Time Limit

0.1~999.9ml / 1 – 2000 mins (Appro. 33 Hrs)

Bolus Functions

‘Hands free bolus – Auto Bolus Mode’ ,
‘Hands on Bolus – Manual bolus’

Maximum Bolus volume

5 ml syringe: 1ml;
10 ml syringe: 5ml;
20 ml syringe: 10 ml;
30 ml syringe: 20 ml;
50 ml syringe: 25ml

Standby time range

00:01-99:59 hh:mm

Alarm Indication - Safety Features

Visual Alarm:
Dual Redundant Visual Alarms both side of the device,
indicates with two priority colors:
Red (High Priority) and Yellow (Low and Mid Priority)

AC/DC indicator :
Light 1 (green)

Battery indicator :
Light 1 (green)

Syringe Brand and Compatible Syringe sizes

The pump is calibrated and labelled for use with
single-use disposable luer lock syringes.
Only use the size and type of syringe
specified on the pump display.
B.Braun : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
B.D : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Dispo Van : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Nipro : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Safti : 5 mL, 10 mL, 20 mL, 30 mL, 50/60 mL
Romsons : 5 mL, 10 mL, 20 mL, 50/60 mL

General Specifications

General Specifications

Display

Screen :
3.0 inch Color LCD screen Display
Resolution:
240 x 128 pixels

Communication Interfaces

Interface ports :
Ambulatory port / 12VDC input,
Nurse Staff Call,
RS 232 – Serial Data port

Power Supply

Integrated Power Supply,
Rated Voltage :
AC 100~240 V, 50~60 Hz,
Power Consumption :
25 VA
External DC power supply :
12V DC supply

Physical Dimensions

Dimension (L) x (W) x (H) in mm:
260 x 148.5 x 134
Weight :
2.2 kg (with clamp base)

Battery

Battery Capacity :
Advanced Rechargeable Lithium Polymer battery –
7.4 V, 4000 mAh (1 Internal battery)

Battery life :
Continuously operate for 6-8 hrs from Full Charge
(at a rate of 5 ml/h at 30°C under Normal Conditions)

Battery Recharge :
When AC Power is ON,
Battery will Automatically Recharge
(about 5 hrs to 90% charge ),
When the pump is off,
the charging time is not longer than 4 hrs

External Fuse

1.5 A / 250 V (User Replaceable)

Environmental Conditions

Operation Conditions:
Ambient temperature: + 5 to + 40°C,
Atmosphere Pressure: 86 ~106 kPa,
Relative humidity: ≤ 80%

Storage Conditions :
Ambient temperature: – 20 to +55°C,
Atmosphere Pressure: 50 ~106 kPa,
Relative humidity: ≤ 95%

Compliance & Essential Performance

Compliance & Essential Performance

Flow Rate Accuracy

Accuracy including syringe:
within ± 2%,

Mechanical accuracy:
within ± 1%

Electrical Safety Protection

Class II protective and internal power supply,
BF Type Equipment,
Mode of operation : 100 % (continuous operation)

Visual Alarm Indication

Visual Alarms indicates with two priority colors:
Red (High Priority) and
Yellow (Low and Mid Priority),
meets according to the IEC 60601-1-8 standard requirements.

Essential Performance

Infusion of liquids without variation of infusion rate
Pressure limitation as protection from the bursting of the infusion line
Protection from air-infusion
Protection against unintended bolus volumes and occlusion (added by IEC60601-2-24)
Alarm signal of high priority (added by IEC 60601-2-24)

Classification

EN / IEC 60601-1 and EN / IEC 60601-2-24 / EMC
Under process – CE Marking in Compliance with the
EU MDR 2017/745 (European Medical Device Regulation)

Class (acc. to Directive 93/42 EEC) : Class IIb

Ingress Protection

Ingress Protection – IP 44
(Complete protection against ingress of
small solid foreign bodies and Water splashed
against the Device from any direction)

Audio Alarm Volume :

Support multi-level volume functions
with the sound pressure range from 59-74 dB(A)
and key pad beep;
The alarm sound meets according to
the IEC 60601-1-8 standard requirements.

Optional Features

Optional Features

Event Log Review

Approximately one year event log of normal use and
Min. 2000 records with time and date

Infusion Management (Optional)

Extensive data connectivity with
Omya’s IMS240i, IMS460i model
(Infusion Monitoring System)

Wireless LAN (Optional)

Wireless Data Transmission compatible with Patient Data Management Systems (Optional)

Nurse Staff call (Optional)

Max. 24 V / 0,5 A / 24 VA

Product Details

Product Images
Explore 360° View

Product Videos

Related Products

Request a quick quote

If you have request of our products or you are interested in any other medical products,
please leave messages below and we’ll reply you soon as possible within 24 hours.

    I agree to have read and understood all the Terms and Conditions

    Omya values and respects your privacy. Please read the Privacy Notice for more information

    Menu